Use and Care Manual
BEFORE USE
• Check the working
area
with the metal locator. be cautious of the inside cable, gas pipe,
and water pipe. Before operating the machine, check supply voltage and general conditions, i.e.
cable/cord damage.
A
machine with damaged cable must be returned or repaired prior to use.
The machine is 110V, the wave motion can not surpass the 10%.
• Set the handle lever into the handle hole and next tighten them.
• Turn
the
handle lever and check
the
guide board to confirm it is moving freely.
Connect the power and open the magnet drill switch. You should see the indicator light up. This means
the magnetic drill i s i n working condition. Use a screwdriver or iron bar in the bottom of magnet to
check whether it has suction. Open the drill control switch and check that the drill is working.
NOTE: When moving the magnetic drill, do not drag it on the ground in order to prevent magnet
damage.
OPERATION
WARNING!
1. Before
operating the machine, check the
supply
voltage and general conditions,
i.o.
cable/cord
damage.
A machine with damaged cable must be returned or repaired prior to use.
2. Always use the safely strap in all drilling applications.
3. Ensure the material to be drilled and magnet both have a clean surface. Material with a
thickness of less than 25mm will not give maximum magnetic adhesion.
4. Since culling tools can shatter, eye and head protection should be worn at all times.
5. After use, clean machine and cutters and keep in the metal case provided.
6. Always provide a method of
catching slug, an ejected slug may cause injury (slug ejects at
end
of cut).
7. Should
the
cutter jam
in the
work piece, stop
the machine
immediately. Isolate the machine at
the main supply. Loosen the cutter by rotating the arbor. Do not attempt to free cutter by starting
and stopping the motor.