3 Getting started
3.1 Installation of software
Note: Do not connect your MVN System (either Access Point or Awinda Station) until software
installation is complete (software installation includes installation of relevant drivers which can
be finalized, when the hardware is connected).
Run the downloaded MVN Installer (mvn_studio#_setup.exe). Install with Administrator rights. Follow
the on-screen instructions.
See 4.1 for details.
3.2 Setup hardware
If using the MVN (BIOMECH) Link system:
Connect the Access Point to the computer using the network cable optionally with the Ethernet-to-
USB adapter. See Section 5.6.
After the suit has been put on, connect the head, hands, and feet trackers to the MTx-STR’s
Place the Body Pack on the right and the Battery Pack on the left of the back (for more information
on putting on the suit, see section 5.9 or the tutorial video (https://tutorial.xsens.com/mvn)).
Connect the Battery Pack and all strings of trackers to the Body Pack
Press the button on the Body Pack once to power on the device, a pulsing fading LED, solid LED,
beep and finally blinking LED indicate the startup process. See Section 5.3.
If using the MVN (BIOMECH) Awinda system:
Connect the Wireless Master to the computer or laptop
Turn on the trackers by pressing the button until each LED is activated and begins to flash
Place the straps and trackers on the body (for more information on putting on the straps, see section
5.9 or the dedicated tutorial video).
Optional if using MVN Studio BIOMECH
Connect the power supply and network cable of the MVN Camera. See Section 5.7.10.
3.3 MVN Studio workflow overview
Run MVN Studio. See Section 6.
Start a new session. See Section 7.1.1.
For MVN Studio PRO or MVN Studio BIOMECH users requiring additional hardware
(reference camera or sync), initialize this hardware at the new session stage.
Check the hardware status to make sure that all trackers that are needed for the given
configuration have been detected by MVN Studio. See Section 7.8.
Calibration. See Section 8.
For this step users should be in an area free of magnetic disturbance. See Section 19.2.
Ensure that the ‘Calibrate’ icon is active in the workflow tool bar.
On the Body Dimensions tab enter the subject height and foot size. See section 8.1.