11.8.5.2 Software Setup in MT Manager
Synchronisation on Sync Out Line 1:
Sync Out
Select Start Recording
Check the check box for Line 1
Polarity: Rising Edge
Trigger Once: Uncheck
Skip first = 0
Skip factor = 0
Pulse width = 10 ms
Select Stop Recording
Check the check box for Line 1
Polarity: Rising Edge
Trigger Once: Uncheck
Skip First = 0
Skip Factor = 0
Pulse width = 10 ms
Set up the wireless configuration in MT Manager.
11.8.5.3 Software Setup Noraxon MyoResearch Software:
The example given below is for is gait analysis, measuring the medial gastrocnemius, tibialis
anterior, semitendinosus and the rectus femoris. For an 8-Channel EMG system, Channel 9 is
selected as the synchronisation line in the Noraxon MyoResearch Software. If a 16 channel
system is in use, this is the 17th channel.
Return to the main menu,
under >Measuring
Options, go to >Recording
Options, then >Triggering
tab.
Check the check box beside “Start Recording”;
Go to the drop down menu beside “When Channel”, select “Sync;
Select Rises Above (ensure that this is also the direction indicated on the mini-
receiver);
Input e.g. 0.5V
Longer than 5ms
Repeat settings for Stop Recording.
Navigate further through the software.