User Manual
© Xsens Technologies B.V.
31
6.6.2.1 Show Docked MTw’s in Device List
This is related to how the Device List handles docked MTw’s. The default setting is to show
docked MTw’s, at all times. If checked (default), docked, and powered on MTw’s will appear
in the Device List, even after wireless configuration. In the Device List it will be possible to
power off, and to observe the battery level of docked MTw’s. If unchecked, after a wireless
configuration, docked MTw’s will not appear in the Device List.
6.6.2.2 Log and Visualize Data for Docked MTw’s
This setting is related to how the recording function handles docked MTw’s. The default
setting is unchecked, which means that data will not be recorded from docked MTw’s. If
checked, data from docked, and powered on MTw’s will be stored in the data files. This may
be useful for users wishing to use for example only the barometer signal from the docked
MTw’s, without using battery power.
Note: If this option is selected, the update rate of these MTw’s is always 100Hz.
6.6.3 Preferences: Logging
Logging/file names.
It is possible to change the naming in
which the log files are saved.
The Xsens default (and recommended) is
“MT_” followed by the device ID and trial
number. However the user may input
custom text, as well as preset values, such
as date, time etc.
6.6.4 Preferences: Exporters
Following a measurement, it is possible to
export the values. Section 11.7 provides a
description of each Orientation Output
Mode.
Note:
1) Acceleration and Angular Velocity are
values derived from the SDI values.
2) Orientation is always exported, as
default. To undo this, select “none” from
the drop-down menu in the list.
6.7 Synchronisation
MT Manager for MTw provides a very easy to use interface, with many possibilities to
facilitate all kinds of synchronisation with third party devices. The user should decide which