Easy Dome TM INSTRUCTION MANUAL
Easy Dome TM INSTRUCTION MANUAL contents Starter Kit Pack p2 Set up Preparing Applicator Gun p3 Preparing Transfers/Labels for Doming p5 Doming Main Points When Doming p6 Applying Resin p6 Using Flame Gun p7 What to do if the resin over-spills p7 Doming Using Xpres Cut Plus (Ultragraphics) p8 Doming Using Versacamm p8 Safety & Technical Data p9 Instructions in this manual refer to Windows 7 and CorelDRAW X5. Other versions may differ.
Set up Preparing Applicator Gun Ensure Plunger is fully retracted. Open clip on the front of the Applicator Gun. Slide the cartridge through the front clip of the Applicator Gun. Close the retaining clip by pulling the cartridge down and wait for the click to signal the cartridge is secure.
Set up Preparing Applicator Gun continued Remove the cartridge cap by twisting through 90 degrees anti-clockwise and pulling to seperate. Attach the Mixer Nozzle to the cartridge by twisting the Mixer Nozzle 90 degrees clockwise into the groves on the cartridge tip.
Set up Preparing Transfers for Doming Before After Transfers should be rounded at the corners, and the corner angle no less than 90 degrees. The ‘corner radius’ should be at least 3mm. Although right angled corners can be domed when care is taken, it is recommended that all relevant corners need to be curved. The example right shows a design where the corners have been adjusted. If left as shown in the ‘before’ diagram the Xpres Easy Dome Resin could over-spill.
Doming Main Points When Doming • Ensure that the working area is well ventilated, clean & free of dust. • Ensure that the working area is level. • Ensure temperatures are kept consistent at all times during the Doming process. Xpres Easy Dome Resin operates best between 17°C - 25°C, and Humidity of 40%. Applying Resin Before applying resin, it is important to hold the cartridge at a 45° upright angle and dispose of the first 1 - 2 grams of resin.
Doming Using Flame Gun If there are any air bubbles in the resin, the Flame Gun should be used. Position the flame gun approximately 3-6 inches away from the surface of the resin and momentarily pull the trigger. The short blast of heat will cause the air bubbles to heat up and rise out of the resin. Before After What to do if the resin over-spills? If the resin over-spills over the edge of the transfers, you can correct small errors using the supplied Repair Stick.
Doming using Xpres Cut Plus If using the Xpres Cut Plus (Ultragraphics) system, Xpres Easy Dome can be used with the following transfer vinyls: Self-Adhesive Doming Vinyl XP4900 (A3) & XP4901 (A4) To be used to create domed self-adhesive labels & signage For best results print with the following quality settings: Paper: Plain paper Quality: Photo Always place Silicon Sheet XP2028 below Self-Adhesive Doming Vinyl before applying Easy Dome Resin in case of overspill.
Safety & Technical Data Important: Safety Guidelines Mixing Information Always use protective gloves and safety glasses. Ratio by Weight Part A 49 Avoid prolonged contact with skin. May cause sensitization by skin contact. Part B 51 Avoid contact with eyes. Part B 50 Ratio by Volume Part A 50 Avoid breathing vapours. Always use in well ventilated area. Curing After contact with skin, wash immediately with soap & water. Gel Time 7-9 minutes, 100 grams @ 100°F If swallowed seek medical advice.
Safety & Technical Data Material Safety Data Sheet Product Name:Z7250 ISO – Part B Date: 10/8/10 1. Product and Company Identification Manufacturers Name Development Associates Inc. 300 Old Baptist Rd. North Kingstown, RI 02852 Emergency Phone No CHEMTREC: (800) 424-9300 24hr Product Name Z-7250 ISO - Part B Chemical Family/Name Aliphatic Polyisocyanate Mixture Trade Name Polyurethane Compound 2.
Safety & Technical Data 7. Handling and Storage Precautions to be Taken in Storage and Handling: Store in tightly closed containers to prevent moisture contamination. Do not reseal if contamination is suspected. If container is exposed to high heat, it can be pressurized and possibly rupture. Diisocyanates react slowly with water to form CO2 gas. This can cause sealed containers to expand and possibly rupture. Avoid contact with skin and eyes.