Axial Fan Owner's Manual Model: X-39AR, X-47ATR (115V 60HZ) Read and save these instructions before use www.xpower.com | 1-(855)-855-8868 | info@xpower.com Index: NA-1-A25 Edition: 2.0.
Safety Instructions ! WARNING - READ AND SAVE THIS INSTRUCTION BEFORE USING THIS PRODUCT. The user of electrical products may create hazards that include, but are not limited to injury, fire, electrical shock. Failure to follow these instructions may damage and/or impair its operation and void the warranty. • Before operating, remove all packaging material and check for any damage that may have occurred during shipping or any missing items.
Items Included Axial Fan Owner's Manual XXX Manual De Usuario (página 10) XXX Mode d'emploi (page 18) Model / Modelo / Modèle: P-80 Series, P-100 Series, P-200 Series (115V 60HZ) Read and save these instructions before use Lea y guarde estas instrucciones antes de usar la unidad Lire et conserver ces instructions avant utilisation www.xpower.com | 1-(855)-8868 | info@xpower.com Index: NA-1-A2 Edition: 1.0.
Parts Description 6 5 7 4 11 2 1 3 8 13 12 8 14 15 9 10 (1) (2) (3) (4) Front Grille Cover Motor Housing Additional Electrical Receptacle (5) Capacitor (6) Housing Handle (7) Switch Plate (8) Rack Handle (9) Rubber Washer (10) Rack (11) Circuit Board Axial Fan Introduction • XPOWER Axial Fans are designed to offer efficient air circulation and ventilation with its high and long-distance focused airflow.
Installation and Operation Guide Installing the Rack* ① ② ① ② ③ ③ ① Fit both rubber washers onto bolts on both sides of unit. ② Align the rack onto the axial fan. ③ Fasten the connection with the rack handle. * For model X-39AR only. Switch Plate MAX OFF LOW Variable Speed Switch • Turn to “OFF” position to switch the Axial Fan OFF. Turn clock-wisely to any position between “MAX” and “LOW” to switch the Axial Fan ON. • You can adjust to any desired speed variably.
Installation and Operation Guide (Continued) Additional Electrical Receptacle (Daisy Chain) CIRCUIT BREAKER 12A TOTAL OUTPUT 12 AMPS MAX WITH THIS UNIT OFF 10 AMPS MAX WITH THIS UNIT ON • Other appliances can be plugged in the additional electrical receptacles and work whether the Axial Fan is on or off. However, the total amperage must be lower than the amperage instructed. Different models may have varying instructions.
Installation and Operation Guide (Continued) Adjust Operation Position • The Axial Fan features 360° Rotation. Tilt the Axial Fan to desired angle and screw on rack handles to secure the fan’s position. Use without Rack* • Uninstall the rack and place the Axial Fan on a level surface. * For model X-47ATR only.
Installation and Operation Guide (Continued) Adjust Operating Position (Continued) Transportation Lift with Handle • Lift the Axial Fan with the handle on the top. User Maintenance Instructions Frequent maintenance is recommended on this appliance. Failure to follow the maintenance instructions may cause failure of the appliance and void the warranty. • When not in use, unplug and store the appliance in a dry and cool indoor place. Make sure it’s out of reach of children.
User Maintenance Instructions (Continued) Fasten the Rack Handles • To prevent possible injury, when you finish using this appliance, please position the Axial Fan UPRIGHT. • Fasten the rack handle to lock the position of the Axial Fan. Organize the Power Cord • Wrap the power cord around the housing. • Clip the cord to the cord clip on the plug shown above.
User Maintenance Instructions(Continued) Stack Multiple Units • Stack the Axial Fans on the sides. Align the air inlets of both Axial Fans. ! WARNING • Do not stack more than five units of this appliance. • Stacking function is not secure during transportation. Troubleshooting Guide PROBLEM Axial fan does not start Unit runs but the speed is abnormal POSSIBLE CAUSE SOLUTION No electricity. Check for power supply. The power cord is not properly plugged in. Remove and reconnect the power cord.
Technical Specification MODEL NUMBER X-39AR Voltage/Frequency Amperage X-47ATR 115 V~60 Hz 1.6 A 2.8 A Motor Power 1/4 HP 1/3 HP Rated Airflow 2100 CFM 3600 CFM Speed Control Timer Variable Speeds N/A 3 hours (OFF) Additional Electrical Receptacles (Daisy Chain) Cord Length Yes 20 ft. / 6.1 m Housing Unit Dimension (L) x (W) x (H) Unit Weight Safety Certification ABS 18.6 x 9.4 x 19.2 in. / 47.2 x 23.9 x 48.8 cm 21.9 x 9.8 x 22.5 in. / 55.6 x 24.9 x 57.1 cm 16.5 lbs. / 7.5 kg 22.2 lbs.
XPOWER Limited Warranty (USA) 1 YEAR LIMITED WARRANTY XPOWER-branded products purchased in the U.S. from authorized distributors include a 1-year limited warranty. Contact XPOWER to confirm warranty information about your product(s). This limited warranty covers defects in materials and workmanship in your XPOWERbranded products, purchased in the U.S. ONLY. Local warranty policy (if any) in your country will cover products purchased outside the U.S.
XPOWER Limited Warranty (USA) (Continued) If you are instructed to return the unit for service or replacement, please: (1) Request a RMA (Return-Merchandise-Authorization) number. (2) Use the original or an equivalent packaging, prepay shipping charges at your own expense to the address provided by XPOWER, with the RMA number on the shipping label or the packaging. (3) Include all the original parts and components. XPOWER will inspect, assess and advise the repairs needed and applicable cost, if any.
English - 14
English - 15
XPOWER Manufacture, INC. 240 Clary Avenue San Gabriel, CA 91776 USA www.xpower.com | 1-(855)-855-8868 | info@xpower.com Read and save these instructions before use Index: NA-1-A25 Edition: 2.0.