User manual

Table Of Contents
Technical Specifications
Technical Specifications
For device technical specifications, go to zebra.com/support.
SE4100 Decode Distances
The table below lists the typical distances for selected bar code densities. The minimum element width (or
“symbol density”) is the width in mils of the narrowest element (bar or space) in the symbol.
Typical Working RangesSymbol Density/ Bar Code Type
Near Far
5 mil Code 39 6.1 cm (2.4 in.) 24.1 cm (9.5 in.)
5 mil Code 128 7.1 cm (2.8 in.) 22.9 cm (9.0 in.)
6.67 mil PDF417 6.1 cm (2.4 in.) 20.3 cm (8.0 in.)
10 mil Data Matrix 7.4 cm (2.9 in.) 22.9 cm (9.0 in.)
100% UPCA 4.6 cm (1.8 in.)* 49.5 cm (19.5 in.)
15 mil QR Code 3.05 cm (1.2 in.)* 30.5 cm (12.0 in.)
20 mil QR Code 3.05 cm (1.2 in.)* 35.6 cm (14.0 in.)
20 mil Code 39 5.08 cm (2.0 in.)* 66.0 cm (26.0 in.)
*Limited by width of bar code in field of view.Notes: Photographic quality bar code at 15° tilt pitch angle
under 30 fcd ambient illumination. Distances measured from front edge of scan engine chassis.
Table 31SE4100 Decode Distances
SE4710 Decode Distances
The following table provides the decode distances for the SE4710 scan engine.
Typical Working RangesSymbol Density/ Bar Code Type
Near Far
4 mil Code 39 8.4 cm (3.3 in.) 22.4 cm (8.8 in.)
Table 32SE4710 Decode Distances
164