User's Manual

Table Of Contents
Product Technical Specification & Customer Design Guidelines
42 Proprietary and Confidential - Contents subject to change 2400074
Inter-RAT and inter-frequency cell reselection and handover between
supported frequency bands
Conducted Rx sensitivity / Tx power
Table 5-1: LTE frequency band support
Band Frequencies
Band 13 Tx: 777–787 MHz
Rx: 746–756 MHz
Table 5-2: LTE bandwidth support
1
1. Table contents are derived from 3GPP TS 36.521-1 v9.4.1, table 5.4.2.1-1.
Band 1.4 MHz 3 MHz 5 MHz 10 MHz 15 MHz 20 MHz
Band 13
2
2. Bandwidth for which a relaxation of the specified UE receiver sensitivity requirement
(Clause 7.3 of 3GPP TS 36.521-1 v9.4.1) is allowed.
2
Table 5-3: CDMA frequency band support
Band Frequencies
PCS Tx: 1850–1910 MHz
Rx: 1930–1990 MHz
Cellular Tx: 824–849 MHz
Rx: 869–894 MHz
Table 5-4: Conducted Rx (Receive) sensitivity LTE bands
LTE bands
Conducted Rx sensitivity (dBm)
Primary
(Typical)
Secondary
(Typical)
SIMO
(Typical)
SIMO
1
(Worst case)
LTE Band 13
Full RB
BW: 10 MHz
2
-97.0
3
-96.5
3
-100.0
3
-93.3
1. Per 3GPP specification
2. Sensitivity values scale with bandwidth:
x_MHz_Sensitivity = 10 MHz_Sensitivity - 10*log(10 MHz/x_MHz)
3. Verizon Test Method
Table 5-5: Conducted Rx (Receive) sensitivity CDMA bands
CDMA bands
Conducted Rx sensitivity (dBm)
Typical Worst case
Cellular (800 MHz)
CDMA 1x
0.5% FER
-108.0 -104.0
EVDO rev A
0.5% PER
-110.0 -105.5