ENGLISH OPTIMA RT9 6KVA / 10KVA USER MANUAL DOUBLE CONVERSION UPS RACK / TOWER UPS Technical information on this manual is property of XMART . This manual Information cannot be copied or distributed totally or partially without written approval of XMART. XMART can introduce modifications in their products or manuals without further notice. . XMART is not responsible of mistakes or missing information in this manual.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ TABLE OF CONTENTS 1. SAFETY 2. AVAILABLE MODELS 3.- UPS INSTALLATION: SITE PLANING SITE INSPECTION & INSTALLATION CONDITIONS RACK UPS INSTALLATION TOWER UPS INSTALLATION EXTERNAL CIRCUIT BREAKERS SELECTION WIRING SELECTION 4.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 1. GENERAL SAFETY INSTRUCTIONS . WARNING: It is required to read and understand this manual. Follow all instructions given in this manual for starting up and operating this product. Only qualified technician must start-up, operate and maintain this product. Keep manuals as a guide for future consults.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ WARNING: BATTERIES MAINTENANCE • • • • • Batteries capacity, in general (of all kinds), decrease with time and use. Our products contain high quality batteries only. Batteries useful life in our UPS is between 4 and 5 years, considering environment temperature under 25 ºC and optimal operational conditions.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 2. AVAILABLE MODELS - OPTIMA RT9 6K / 10K: UPS including UPS Module and Batteries Module with DC connector for additional external batteries Rack-Tower mounting Input / Output: 1Ph 208/220/230/240Vac. Components: 1 module (3U) with UPS electronic set. 1 module (3U) with UPS batteries.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ RACK: RACK 6KEX / 10KEX UPS MODULE 1. RS-232 2. USB 3. EPO” (Emergency Power Off): Open = Power Output OFF / Close = Function disable 4. Share Current Port (for parallel function) 5. Parallel Port (for parallel function) 6. SNMP Intelligent Slot 7. Cooling Fans 8. External Bypass Switch port (MBS port) 9.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 3.- UPS INSTALLATION: SITE PLANING SAFETY INSTRUCTIONS WARNING: Before revising this section you must read and understand very well section 1 of this manual: “GENERAL SAFETY INSTRUCTIONS”.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ SITE INSPECTION AND INSTALLATION CONDITIONS REGULATIONS AND LEGAL DIRECTIVES It is necessary to check that installation site, wiring and power protection in the installation supplied by end user, fulfill technical parameters required by UPS.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ RACK UPS INSTALLATION Rack UPS must be installed using L-Shape type guides for supporting UPS weight. Usually this kind of supports is provided with rack cabinets. If not, UPS distributor can provide original telescopic guides as optional accessory. Small black handles included with the UPS are only for locking purposes.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ TOWER INSTALLATION This UPS can be also installed as tower UPS as indicated below. UPS + BATTERY MODULE = 2 MODULES www.xmart-ups.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 3 MODULES = UPS + BATTERY MODULE (EXBATT) + ISOTX www.xmart-ups.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ ELECTRICAL REQUIREMENTS (MANDATORY) * All Power lines must be protected by magneto-thermal protection devices against over current (breakers) with capacity and technology appropriate to effectively accomplish its function as indicated in this manual. Moreover, installation grounding must be correct.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ CIRCUIT BREAKERS AND WIRING SELECTION Breakers and Gauge of the wires used in the installation must be rated to drive current values in Amps as indicated in below tables. NOTE every country has its local electrical requirements and regulations.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 4.- UPS INSTALLATION: SINGLE UPS - TERMINAL BLOCK AC LINES CONNECTION PROCEDURE • Make sure the UPS is Off before starting the installation. • Remember to check all wires to be connected are not powered (including external batteries).
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ UPS TO ISOTX WIRING ISOTX module is an optional accessory rack module that offers 2 isolated 120Vac outputs. UPS AC output must be connected to ISOTX input as indicated. www.xmart-ups.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ ISOTX TERMINAL BLOCK www.xmart-ups.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ ISOTX OUTPUT CONFIGURATIONS ISOTX outputs can be configured in 3 different manners as detailed in this section. www.xmart-ups.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ EXTERNAL BATTERY CABINETS – CONNECTION PROCEDURE 1.- Check all DC breakers are in OFF position 2.- Remove all DC connector covers in UPS and EXBATT cabinets 3.- Using appropriate cable (supplied with the EXBATT) connect UPS with EXBATT 1. In case of more than 1 EXBATT connect EXBATT 1 with EXBATT 2 and so on until last EXBATT.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 5.- UPS INSTALLATION: PARALLEL UPS - TERMINAL BLOCK . GENERAL COMMENTS FOR PARALLEL SYSTEMS 6K y 10KVA models allow installation of up to 3 units in parallel. Units to work in parallel must be connected as indicated in this section.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ PARALLEL - UPS RT9 - AC LINES CONNECTION - 2 & 3 UPS www.xmart-ups.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ PARALLEL - USING ISOTX - AC LINES CONNECTION ** NOTE 1: WARNING: In parallel systems with ISOTX modules, to avoid permanent damage or incorrect operation, it is important to connect output neutral between all UPS as indicated in above drawing. www.xmart-ups.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ PARALLEL UPS - CONTROL WIRES CONNECTION www.xmart-ups.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 6.- START-UP: SINGLE UPS INSPECTION BEFORE START UP 1. 2. 3. 4. 5. 6. Make sure all wires are tightly connected to terminal block. Any loose connection will produce overheating, failures and damage to UPS. Make sure all instructions of sections 3 and 4 have been performed correctly.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 7.- START-UP: PARALLEL UPS REQUIREMENTS FOR PARALLEL SYSTEM WARNING: Before starting up this parallel UPS system is mandatory to comply with all below requirements. 1.- Maximum quantity of UPS to be connected in parallel is 3. Do not try to connect more than 3 units in parallel. 2.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ START UP FOR PARALLEL UPS SYSTEM WARNING: Make sure all requirements and previous inspection have been revised and complied before initiating start up procedure. If not please do not try to continue with start-up procedure. 1.- Make sure all equipments to be protected and connected to UPS output are in OFF condition. 2.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ ** If deviation is higher than 2Vac, we suggest to adjust voltage output in UPS by SETTING / CALIBRATION / INVERTER section of configuration menu. Setting: Control Measurement Information Setting Alarm Bypass ECO Output Battery Calibration Others Calibration: Batt: 273.0 +0,0 Inv: 220.0 +0,0 Chg: 273.0 +0,0 13.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 8.- OPERATION INTERFACE UPS FRONT PANEL: PUSH BUTTON ON / ENTER OFF / ESCAPE ON : Goes directly to "TURN-ON" menu. ENTER : It works as or confirmation key for screens options OFF : Goes directly to "TURN-OFF" menu. ESCAPE : It works as key for screens options.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ UPS FRONT PANEL: LCD This UPS has a sophisticated LCD able to display all important information related to input line, UPS status and values, operation mode and error and alarm messages. It is a powerful information tool to know what is happening at any moment.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 9.- OPERATION: SINGLE UPS This is a True On Line Double Conversion UPS and it is designed to offer clean, bump-less and highest quality power to your computer related equipments protecting also your valuable data. Power delivered by UPS is 100% sine wave as main line.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 10.- OPERATION: PARALLEL UPS UPS operation modes for UPS in parallel are basically same than described for single UPS. However it is important to remark all UPS in parallel system must work under same mode at same time. Parallel function does not allow different operation modes between UPS of the system.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 11.- UPS CONFIGUIRATION MAIN INTERFACE SCREEN: This is the first screen presented on LCD when UPS is powered on (without turning UPS on). If front panel is not operated LCD will go to this screen after few seconds. Bypass Mode IP: 208.0V / 50Hz OP: 208.0V/50Hz Batt: 273.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ Configuration menu functions and screens Screens menu is divided in 5 different modules as follow: F1. CONTROL F2. MEASUREMENT F3. INFORMATION F4. SETTING F5. ALARM www.xmart-ups.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ F1. CONTROL FUNCTIONS: Control Line Mode Turn On ? --> Turn On Batt Test Mute Para Unlock --> Yes No Control IP: 208.0V / 50Hz OP: 220.0V/50Hz Batt: 273.0V/99% Load: 50% Battery Test Mode Battery Test ? Turn On --> Batt Test Mute Para Unlock --> Yes No Control IP: 208.0V / 50Hz OP: 220.0V/50Hz Batt: 245.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ F2. MEASUREMENT FUNCTIONS Input: 1/5 Volt: 220.0V Freq: 50.0Hz Bypass: 4/5 Volt: 220.0V Freq: 50.0Hz Output: 2/5 Volt: 220.0V Current: 43,0A Freq: 50.0Hz Inv: 220.0V Apparent Power: 10000VA Active Power: 9000W Load: 100% Charger: Battery: 3/5 Volt: 273.0V Cap: 100% Discharge Time: 00:00:00 5/5 Volt: 273.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ F4. SETTING FUNCTIONS This menu is used to adjust most important parameters of the UPS as described in below screen. Some of below settings cannot be changed in all operation modes. Please check functions availability according to UPS mode in first page of this section.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ SETTING / ECO STATUS ENABLE: ECO function enable STATUS DISABLE: ECO function disable ECO: --> Status: High Loss: Low Loss: High Loss: Low Loss: Disable 232V 184V 52Hz 48Hz HIGH LOSS V: Acceptable high limit for input voltage for UPS in ECO mode. LOWLOSS V: Acceptable min. limit for input voltage for UPS in ECO mode.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ SETTING / BATTERY Battery: --> DisChg Protect: Enable 990 min. Batt Test Type: Till Batt Low DISCHARGE PROTECTION FUNCTION: Enable: UPS will shutdown automatically to protect batteries. Shutdown will be produced according to time in minutes set below (from 000 to 990 min.) Disable: Batteries protection disable.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ SETTING / OTHERS HOT STANDBY: Others: --> ENABLE: It allows UPS to restart after a long AC failure even UPS has no batteries connected. Hot Standby Backup Time DISABLE: It allows UPS to work as standard UPS. It will only restart when AC recovery is detected if UPS has batteries connected.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 12.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 13.- TECHNICAL SPECIFICATIONS ONLINE RT9 UPS Capacity / Capacidad Output PF / FP de Salida: 6K-RT9 10K-RT9 6KVA / 5.400W 10KVA / 9.000W 0.9 0.
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ ONLINE RT9 UPS 6K-RT9 10K-RT9 INDICATORS / INDICADORES LCD / Pantalla LCD UPS status, Load level, Battery, Input/Output voltage, Discharge timer, and Fault conditions Estado del UPS, Consumo, Baterías, Voltaje Entrada-Salida, Tiempo Descarga, Diagnostico ALARM / ALARMAS Beep Alarm / Alarma sonora: For Battery Mode, Low ba
User Manual - ONLINE 6K/10K RACK-TOWER ISOTX UPS ENGLISH __________________________________________________________________________________________________________________________ 14.- LIMITED WARRANTY Support: If a failure or problem is detected please check troubleshooting section in user manual. If problem cannot be solved please contact authorized service center or authorized dealer. Batteries: Rechargeable batteries can be charged and discharged hundreds of times.