11.2. ANN-6L SIX ZONE ANNUNCIATOR
For situations that warrant using the HALO Controller in a stand-alone configuration, without the
Computer Console, the ANN-6L may be used as the annunciator panel. The ANN6L is a six-zone central
alarm panel, usually mounted at the nursing station, reception or a guard station to monitor the status of up
to 6 alarm zones. Each additional ANN-6L will allow six more zones to be monitored. The reset switches
can be ganged so that only one reset switch needs to be pressed to reset all the panels.
Alarms can also be monitored at separate locations with additional ANN-6L panels. These secondary
panels provide either common or local alarm status. Reset can be performed on any ANN-6L when used for
common alarm indication.
Six Bi color LEDs indicate alarm priority.(red = latching : yellow = non-latching)
Two distinctive piezo alarms indicate alarm priority. These may be disabled during install.
Latching and non latching alarms.
Alarm inputs accepted via N/O or N/C dry contacts or a voltage transition (switch selected
function)
Reset function can be ganged with other annunciator resets for remote operation
Silence button deactivates audible alarm, new alarms activate audible alarm
Onboard Form C relay for auxiliary output.
Mounts in a standard 2 gang electrical box. (supplied)
External speaker output provided