Operations Manual
EXI HALO Installation & Operation Manual 981-000003-000
EXI Wireless Systems 45 March 2000
Revision 2.0
9. DKX KEYPAD PROGRAMMING
The Keypad is pre-programmed for the following:
• BYPASS FUNCTION: 1938
• RESET FUNCTION: 1939
To re-Program Keypad:
1) BEGIN programming mode enter: * 382436#
- 3 beeps indicate a valid program code was entered.
2) DELETE all codes enter: *12#
- The code to be deleted must be entered twice. Any outputs assigned to this code do not need to
be entered: Example to delete the code 1938 enter *12 1938#1938#
3) SET code length enter: *19_#
- You may set the code length for 3, 4, 5 or 6 digits. The number entered after *19 dictates the
number of digits in your code.
Example *194# was used to set program for 4 digits.
4) ASSIGN user codes enter: *11_ _ _ _ _ _ # _ #
- The number of codes digits entered depends on the code length selected in the option *19
- The program codes with these selectable outputs.
a) Main Relay Bypass function
b) Aux Relay Reset function
Example 1: *11 1938## was used to set the Main Relay Bypass function so that it
operates when 1938 is entered on the keypad.
Example 2: *11 1939 was used to set the Aux Relay Reset function so that it
operates when 1939 is entered on the keypad.
5) Set the MAIN RELAY BYPASS function time enter: *21_ _#
- Programs the Main Relay Bypass function
Example: *2101# was used to set the main relay bypass function.
6) Set the AUX RELAY RESET function time enter: *22_ _#
- Programs the Aux Relay Reset function
Example: *2201# was used to set the aux relay reset function.
7) EXIT program mode enter: *99#
- EXIT program mode and allows the keypad to return to “on line”