Operations Manual
EXI HALO Installation & Operation Manual 981-000003-000
EXI Wireless Systems 33 March 2000
Revision 2.0
Controller Input Switch State Result
Closed
Unlock In
Open
Closed Force Door Lock
Open Normal Operation
Controller Disabled
Override In
Normal Operation
7.4.KEYPAD
The Keypad provides the user with four separate functions.
Local audible and visual alarm,
Allows bypass function,
Reset the alarm when the controller is in continuous alarm mode, or reset the bypass sequence
Controller status indication via the keypad LEDs.
member needs to be able to initiate a bypass function from either side of the door, there will have to be two
Keypads installed. A “Y” Cable adapter is available to easily connect the two keypads to the door controller.
Figure 25 – Keypad Indicator Functions
INDICATORS
STANDBY
MODE
ALARM MODE
BYPASS
MODE (1938)
RESET
MODE (1939)
READER
MODE
YELLOW ON ON ON ON ON
RED OFF ON (FLASHING) ON (FLASHING) X=don’t care OFF
GREEN OFF OFF ON (FLASHING) X=don’t care ON
JUMPER J1 settings on Halo
Controller
Position 2 for DKX Keypad operation.
Position 1 for RBC Keypad operation.
Standby:
Yellow
Bypass:
Green
Alarm:
Red