Table 5: (Continued) Address Switch
Address
ABCDEFGH
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
Table 5: (Continued) Address Switch
Address
ABCDEFGH
Proximity Tag Reader Location
Maximum Tag detection range is approximately 5 ft. (1.5 m). As a result, mount the PTR
very close to the tag detection location. For example, to detect a tag worn by someone
in a bed, wall mount the PTR at the head of the bed.
The PTR case was designed to make options and adjustments user-inaccessible. Unlike
other RFID devices, the PTR is designed for mounting in locations visible to the facility
occupants.
Setting LF Field Strength
Varying the LF field strength changes the size of the Tag detection zone.
Use Test Mode to set the LF Field Strength. Test Mode provides an audible beep; and,
disables network messaging.
Tools: You will need a VeriChip RFID Tag and a small common screwdriver.
To adjust the LF field strength:
1 Choose the PTR’s final mounting location.
2 Use the backplate to mark the wall.
3 Drill mounting holes in the wall.
4 Remove the PTR cover. Identify the Options Dip Switch as shown in Figure 2.
Figure 2: PTR Circuit Board
Page 4 981-000300-000 R1.00 (Draft)
4 Pin Wiring Connector for
Power and Optional Input
Green LED
Red LED
Address DIP Switch
Options DIP Switch
RF Field Strength
Adjustment
Proximity Tag
Reader Circuit Board