6. ECO-Lite Controller
The ECO-Lite has 3 lights to indicate status:
Green Yellow Red
(Standby) (Bypass) (Alarm)
Front View
“GREEN LIGHT”
indicates the power is on and the system is on standby.
“RED LIGHT”
FLASHING indicates an alarm is in progress (tag detected in range).
“YELLOW LIGHT”
&
“RED LIGHT”
alternately FLASHING indicates the system is in
BYPASS Mode.
Back View
Side View
8 Position rotary switch
use to
set the ID address between the
keypad and controller.
Auxiliary Port
: 1 set of N/O & N/C
relay contacts to drive external devices.
(cameras, sounders, magnetic locks)
Potentiometer
used to adjust
the field detection zone (3’-12’)
Maximum: Fully Clockwise
Input power
from
wall mount adapter
24V @ 500mA
Back-up battery switches.
Shipped in OFF position. Turn
both switches ON to activate
back up battery supply.