5. Initializing the ECO-Lite System
Before using the ECO-Lite System, the wireless keypad must be configured to communicate with the con-
troller. The following procedure follows:
1. Plug in the 24V AC adapter into the controller power jack.
2. Preset the rotary switch SW100 on the controller to match the keypad (position 0-7).
3. Type Master password
(9876- Factory Default)
on keypad and then press the ‘Enter’ key. (The green
bypass led should blink on the keypad)
4. Type number (1) on the keypad.
5. Press ‘Enter’ key.
6. Press ‘Clear’ key. (Hear a short beep)
7. Type Master password
(9876 - Factory Default)
on keypad and then press the ‘Enter key’.
8. Enter number (1) on keypad and press the ‘Enter’ key.
9. Type in a 4-digit code
”XXXX”
and press the ‘Enter’ key. (Hear 2 short beeps)
The controller should now be configured to communicate with the keypad.
To confirm, retype the 4-digit code on keypad and press ‘Enter’ key.
You should hear an alarm accompanied by alternating red and the yellow LEDs.
If no alarm, then repeat the configuration process, ensuring that the keys are pressed properly each time you
enter a number.
After the controller has been configured, each time that you enter the 4-digit code, a low tone alarm should
go off and you should see alternating red and yellow LEDs on the controller.
Rechargeable Back-up Battery Switch
Shipped from the factory in the
“OFF”
position. Turn both switches to the
“ON”
position to activate the
rechargeable back up battery supply in case of a power failure.