User's Manual

Compact eLink Reader 981-000037-000
eXI Wireless Systems 16 July 2003
Revision 1.0
DC Com/Sig Gn
d
+ 12Vdc
P1A
WECO 120-A-111/10-CN
10
9
8
7
6
5
4
3
2
1
10
9
8
7
6
5
4
3
2
1
Relay NO
Door SW
DC Com/Sig Gn
d
Bypass
Not Used
Not Used
Relay NC
Relay COM
Relay is activated on alarm: Contacts are rated 1.0 A, 30 VDC or 0.5A,
125VAC
Bypass can be used for manual switch control: a momentary switch clos-
ing pin 5 to Sig Gnd will bypass the alarm. Input impedance is 10 kOhm
biased at 5 Vdc
A switch closure between pin 4 and Sig Gnd will activate the alarm: Input
impedance is 1 kOhm biased at 5Vdc.