3. EVENT DESCRIPTION AND DEFAULT MASK
3.1. [6070] WAKE ON SOFTWARE RESET
Wake on Software Reset event is triggered by device power up or reset.
Default String UID, EV#, D, T, LT, LN, AL, SP, HD, SV, HP, BV, CQ, MI, GS, EA, BB, PM, AX, AY, AZ, SEQ
3.2. [6071] WAKE ON MOTION START
Wake on Motion Start is triggered by exceeding the accelerometer threshold within a specified time window. The
thresholds are configured with the !cs:56 command.
Default String UID, EV#, D, T, LT, LN, AL, SP, HD, SV, HP, BV, CQ, MI, GS, EA, BB, PM, AX, AY, AZ, SEQ
3.3. [6072] WAKE ON MOTION STOP
Wake on Motion Stop is triggered when the device does not exceed the accelerometer threshold within a
specified time window. The thresholds are configured with the !cs:56 command.
Default String UID, EV#, D, T, LT, LN, AL, SP, HD, SV, HP, BV, CQ, MI, GS, EA, BB, PM, AX, AY, AZ, SEQ
3.4. [6074] WAKE ON PERIODIC MOTION
Wake on Periodic Motion event is triggered when the accelerometer remains above the motion threshold during
a specified time window. The thresholds for the time window and accelerometer are configured with the !cs:56
command.
Default String UID, EV#, D, T, LT, LN, AL, SP, HD, SV, HP, BV, CQ, MI, GS, EA, BB, PM, AX, AY, AZ, SEQ
3.5. [6075] WAKE ON PERIODIC NO-MOTION
Wake on Periodic No-Motion event is triggered when the accelerometer remains below the motion threshold
during a specified time window. The thresholds for the time window and accelerometer are configured with the
!cs:56 command
Default String UID, EV#, D, T, LT, LN, AL, SP, HD, SV, HP, BV, CQ, MI, GS, EA, BB, PM, AX, AY, AZ, SEQ
3.6. [6112] SYSTEM VERSION REPORT
Reports firmware versions for the PSOCapplication, PSOCboot, SC20 application, SC20 system, and door sensor.
Before version DBz1.1178AA2.2 System Version was triggered on every reset.