Product Manual

Table Of Contents
XT3182D Product Manual
Page 34 | 37
CONFIDENTIALAND PROPRIETARY
6.7. MONOMO
6.7.1. Configure Monomo Wakes
Command Type Syntax
Command
!cs:56,<mo_window>,<mo_hit>,<mo_per>,<nomo_window>,<nomo_hit>,<nomo_
per>,<flags>
Response
Parameter Type Description
mo_
window
Window for a no-motion to motion transition.
mo_hit Required percentage of motion samples within that window to cause the
transition.
mo_per Time in seconds for a periodic motion wake.
nomo_
window
nomo_hit
nomo_per
flags Hex mask of wake events.
Index Descriptions
0 Transition to motion
1 Transition to no motion
2 Motion periodic
3 No-motion periodic
6.8. SC20 GPIOS
GPIO Set Command Clear Command
Gps-Green !npscmd:!is:69 !npscmd:!ic:69
GPS-Red !npscmd:!is:89 !npscmd:!ic:89
IR1 !npscmd:!is:9 !npscmd:!ic:9
IR2 !npscmd:!is:10 !npscmd:!ic:10
IR3 !npscmd:!is:11 !npscmd:!ic:11
IR4 !npscmd:!is:95 !npscmd:!ic:95