Product Manual

Table Of Contents
XT3182D Product Manual
Page 33 | 37
CONFIDENTIALAND PROPRIETARY
6.6. DOOR SENSOR
6.6.1. Set Door Sensor mac Address
Command Type Syntax
Command
!mcs:25, <mac>
Response
Parameter Type Description
mac Hex
String
mac is a 12 character hex string. E.g., "a4da32067f71"
6.6.2. Configure Door Sensor Wakes
Command Type Syntax
Command
!cs:60,<open_per>,<closed_per>,<flags>,<angle>
Response
Parameter Type Description
open_per Periodic wake when door is open (seconds). Default value is 900 (15 minutes).
closed_
per
Periodic wake when door is closed (seconds). Default value is 21600 (6 hours).
flags Hex mask of wake events.
Index Descriptions
0 Open event
1 Close event
2 Open periodic event
3 Closed periodic event
angle The threshold for a closed door (degrees). Default value is 10.