4.10. MOTION SENSITIVITY (MST)
Configuration instances: 1
Command Type Syntax
SET Command
:wycfg mst <motion_sensitivity_value>
Response
:OK
READ Command
:rycfg mst
Response
| mst: motion:<motion_sensitivity_value> (hex_val)
:OK
Parameter Range Description
motion_
sensitivity_
value
1 to 2000 Configure accelerometer motion sensitivity in thousandths of a unit of
gravity.
4.11. SERIAL PORT SETTINGS (SPS)
l sps[0] -> Aux port 0
l sps[1] -> Aux port 1
Configuration instances: 2
Command Type Syntax
SET Command
:wycfg sps[x] <baudrate> <dps_value> <mode_value> <console_print>
Response
:OK
READ Command
:rycfg sps[x]
Response
|sps[x]: baud:<baudrate> (hex_val), dps:<dps_value> (hex_val), mode:<mode_value>
(hex_val), conprt:<console_print> (hex_val)
:OK