- 1. Functional Description
- 2. Device Setup
- 3. Interfaces
- 4. Device Configuration
- 4.1. APNs (apn)
- 4.2. OBD Accel and Decel (oad)
- 4.3. OBD RPM and Speed Events (ors)
- 4.4. OTA Prevent (ota)
- 4.5. Bluetooth Enabled (blt)
- 4.6. Buzzer Songs (bzr)
- 4.7. Destination (dst)
- 4.8. Generic Config Value (gcv)
- 4.9. Input Default Polarity (idp)
- 4.10. Motion Sensitivity (mst)
- 4.11. Serial Port Settings (sps)
- 4.12. Timer Duration (tmr)
- 4.13. Packet Creation Recipe (pcr)
- 4.14. Third-Party Config Values (tpv)
- 4.15. GPS Solution Filter (gsf)
- 4.16. Vehicle Bus Configuration (vbs)
- 5. Interpreter
- 6. Command Language
XT2500 Product Manual
Page 15 | 92
CONFIDENTIAL AND PROPRIETARY
4.9. INPUT DEFAULT POLARITY (IDP)
l idp[0] -> PUD on user input 1
l idp[1] -> PUD on user input 2
l idp[2] -> PUD on user input 3
l idp[3] -> PUD on user input 4
Configuration instances: 4
Command Type Syntax
SET Command
:wycfg idp[x] <pullup_disable>
Response
:OK
READ Command
:rycfg idp[x]
Response
| idp[x]: polrty:<pullup_disable> (hex_val)
:OK
Parameter Range Description
Input active
level
0 to 1 Sets the corresponding user input "active" level by engagingan external
pullup ('0') or pulldown ('1') oncorrespondingthatuser input.
An idp setting of '1' means the user input is configured active high, so the
user input is pulled down when not driven by external influences.
An idp setting of '0' means the user input is configured active low, so the user
input is pulled up when not driven by external influences.