For instance in this matrix:
Oscillator 1 saw output is connected to the filter
audio input.
Filter audio output is connected to the VCA audio
input (named ENV as in the original model)
Finally output VCA (ENV. SIGNAL) is connected to
the output of the synthesizer (OUT 1/2)
Connection is always made from left to right and
bottom to top.
The matrix can sometimes seem too small. Clicking on the magnifier, or using the mouse-wheel over the
matrix, will open it in a big pop-up, for an easier reading experience.
When a connection is made, you can adjust the amount by clicking and moving the mouse. The pin will
turn, giving you an idea of the current value. Turned fully to the right, the value is at a positive maximum.
Turned fully to the left, the value is at a negative maximum.
The color of the pin helps you to see the adjusted value, and its polarity (positive or negative), in a glance.
To remove a connection, just right click on a pin.
For a trig connection, there is obviously no amount setting.
10 XILS 4 Trig connection description
As we explained, there are absolutely no internal or default connections in the XILS 4. This means that
even the connection between the keyboard and the envelopes, for instance, must be made.
Two trig sources are available: the Keyboard and the Sequencer. They are grouped in two different panels:
You will find the Keyboard trig matrix at the right of the virtual keyboard, and the Sequencer matrix in the
sequencer/module panel (under the tab “seq connection”)
A “trig” connection is connecting a “trig” or “gate” signal to an envelope, sequencer start, stop, or LFO
reset.