Using the Optional Management Interface
R
-- DISCONTINUED PRODUCT --
There are two different transaction types of MDIO for write and read. They are described
in this section.
Abbreviations Used
The following abbreviations apply for the remainder of this chapter.
PRE Preamble
ST Start of frame
OP Operation code
PHYAD PHY address
REGAD Register address
TA Turnaround
Write Transaction
Figure 8-6 shows a write transaction across the MDIO, as defined by OP=’01.’ The
addressed MMD (PHYAD) device takes the 16-bit word in the data field and writes it to the
register at REGAD.
Figure 8-5: Typical MDIO-managed System
MAC 1 MAC 2
STA
mdc
mdio
MMD
MMD
MMD
MMD
MMD
MMD
Figure 8-6: MDIO Write Transaction
Z1 1 1 0 0 1 P4 P3 P2 P1 P0 R4 R3 R2 R1 R0 1 0 D15
D14
D13
D12
D11
D10
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
1 ZZZ
mdc
mdio
IDLE IDLE32 bits
PRE
ST OP PHYAD REGAD TA 16-bit WRITE DATA
STA drives MDIO