5.6. Power button and status indicator
Power button
Plug in the battery, the default power is on
Long press for 5 seconds to turn off the power
Long press for 3 seconds to turn on the power
Indicator light
Module registration
It will be on for 2ms every 2s until the registration is successful and the device enters sleep
or long sleep, the light is off.
When the device is successfully registered
Every 500ms, it lights for 2ms and lasts for 5s.
During normal work
2ms on every 1 minute