Specifications

ZETA AP Micro
8
6. System Testing
Three minutes after the gateway is powered on, the online information
of the gateway can be seen on the IoT platform;
After the gateway is online, it can be connected to the lower-level
network element equipment, and the data of the lower-level network
element equipment is uploaded to the platform for display through the
gateway route;
7. Common faults and handling
Check the power supply to ensure that the gateway is powered
normally.
Check the antenna, whether the antennas are connected correctly, and
whether they are properly tightened.
Check the network cable and check if the network cable is properly
connected.
Check the status light to check whether the two status lights on the
gateway core board are normal (one is always on, and one flashes
twice in one second)
View the platform device status. In the (Management Platform -
Gateway Management) list, check whether the current device status is
"Online".
Check whether the heartbeat packet of the gateway (once per minute)
is normal.
If it still does not work, you can power it on again, start the gateway
device, and check to see if it is restored.
Contact ZiFiSense for more solutions.