User's Guide
AM100 Series User Guide
6
PIR
Detection Area 94 ° Horizontal, 82 ° Vertical
Detection Distance 5 m
Output Range 0-65535
Light
Range 60000 lux (Visible + IR, IR)
Accuracy ±30%
CO2
N/A
Range 400 - 5000 ppm
Accuracy ±30 ppm or ±3 % of reading
TVOC
Range 0 - 60000 ppb
Accuracy ±15 %
Long-term Stability 1.3 % accuracy drift per year
Barometric Pressure
Range 300 - 1100 hPa (-40°C - 85°C)
Accuracy ±1 hPa
Display & Configuration
Display 2.13-inch Black&White E-Ink Screen
Configuration
1. Mobile APP via NFC
2. PC software via NFC or type-C USB port
Physical Characteristics
Power Supply 1. 2 × AA Alkaline battery
2. 5VDC type-C USB power supply
Battery Life
1
(10 min interval, SF7-SF10)
0.9-0.7 year
0.8-0.6 year (Smart Mode Disabled
2
)
1.5-1.2 year
1.3-1 year(Smart Mode Disabled)
VOC Disabled
1.1-0.9 year
1-0.8 year(Smart Mode Disabled)
Operating Temperature 0°C to +45°C
Relative Humidity 0% to 100% (non-condensing)
Dimension 105 × 70.4 × 21.2 mm (4.1 × 2.8 × 0.8 in)
Mounting Wall
1. Battery life is indicative only.
2. Smart mode: PIR=0 and last 20mins, the screen will stop updating data. It’s recommended open this mode.