User's Guide

AM100 Series User Guide
27
Humidity Calibration
Enter the calibration value for humidity.
Note: only integer is allowed.
Null
Illumination
Calibration
Enter the calibration value for illumination.
Note: only integer is allowed.
Null
TVOC
Calibration (AM102 Only)
Enter the calibration value for TVOC.
Note: only integer is allowed.
Null
CO2
Calibration (AM102 Only)
Enter the calibration value for CO
2
.
Note: only integer is allowed.
Null
Barometric Pressure
Calibration (AM102 Only)
Enter the calibration value for barometric
pressure.
Note: only one decimal is allowed.
Null
Note: Calibration value should be re-configured if you re-start one item collection in Data
Collection page.
7.2.3 Threshold
Location:
Ursalink ToolBox (PC): Device Settings Threshold Settings
Ursalink ToolBox (APP): Device Settings Threshold Settings
Threshold Settings
Item Description Default
Temperature
Enable: The device will send the latest temperature
value to Network Server if the temperature
goes
above/below
temperature thresholds.
Disabled
Over The maximum temperature threshold. Null
Below The minimum temperature threshold. Null
Example: Set the "Lockout Time" for 10min, "Duration" for 5min.
The device will report the detected value immediately when the value reaches the threshold and
last for 5mins. After that, the device will check the detected value every 10 mins, and report the
value again if it reaches the threshold and last for 5mins.
8.Sensor Management via Ursalink Cloud
Ursalink cloud is a comprehensive platform that provides multiple services including device
remote management and data visualization with the easiest operation procedures.
8.1 Ursalink Cloud Registration
Register and log in Ursalink Cloud.
Ursalink Cloud URL: https://cloud.ursalink.com/login.html