User's Guide

12
Reporting interval > 30 mins: the device will send specific mounts of
LoRaMAC packets every to check connection status every reporting interval;
If no reply after specific packets, the device will re-join.
ADR Mode Allow network server to adjust datarate of the device.
Note:
1) Please contact sales for device EUI list if there are many units.
2) Please contact sales if you need random App keys before purchase.
3) Select OTAA mode if you use Milesight IoT cloud to manage devices.
4) Only OTAA mode supports rejoin mode.
4.3 Interface Settings
UC50x series support data collection by multiple interfaces including GPIOs, analog inputs and
serial ports. Besides, it can also power the terminal devices by power output interfaces. Basic
settings are as follows:
Go to General -> Basic of ToolBox software or Setting -> General Settings page to change
the reporting interval.
Parameters Description
Reporting Interval
Reporting interval of transmitting data to network server. Default: 20
mins, Range: 1-1080 mins.
Note: RS232 transmission will not follow the reporting interval.
The device returns
to the power supply
state
If the device loses power and return to power supply, the device will be
on or off according to this parameter.
Interface 1/2 3V3 Enable 3.3V power output. After enabled, the power output will supply