Installation Instructions
USER MANUAL
15
7. Wire The Circuit
WARNING:
This device must be grounded. Disconnect electrical
power prior to installing the charging station.
WARNING: Improper connection of the equipment-grounding
conductor would result in a risk of electric shock. Check with a
qualified electrician or serviceman if you are not sure whether
the product is properly grounded. Do not modify the plug
provided with the product – if it doesn’t fit the outlet, have a
proper outlet installed by a qualified electrician.
CAUTION: Use appropriate protection when connecting to the
main power distribution cable.
For safe use of electricity, please set circuit
breaker protection in the input part of EV Charger
The wiring is not complicated, just need to follow
the instructions below:
Connect the L1 lead to the grid L1, connect the L2
lead to the grid L2, connect the PE lead to the grid PE.
Circuit Breaker Options table
Output Amperage (A)
16A
32A
40A
48A
70A
80A
Circuit Breaker Options (A)
20A
40A
50A
60A
90A
100A