User's Manual

4
WARNING
These radio systems shall be installed by a RF/radio professional familiar with the
applicable rules. Installation of all antennas shall be performed in a manner that will
provide at least the MPE Distance from the direction of maximum radiation, to any user
or member of the public and consistent with the settings in the applicable antenna
installation compliance section below.
FCC antenna compliance
Since professional installation is required, standard RF connectors are used. Adapters or
custom coaxial cables may be required to connect the radio output connector to the
desired antenna.
Any antenna from a reputable manufacturer with desired bandwidth, gain/pattern
coverage, and have an input surge impedance of approximately 50 ohms can be used.
Maximum antenna gain is 11 dBi in both the 757-758MHz and 787-788 MHz bands.
However, for 11 dBi antenna gain, maximum output power must be reduced at the
radio output or cable with loss of at least 5dB must be employed. It is recommended to
use a low gain antenna, with max gain of 6dBi in the 787-788 MHz bands.
Exposure Compliance
FCC ID: PEJ-9382009
It is the responsibility of the licensee or user to guarantee compliance with the
appropriate MPE regulations when operating this device in a way other than described
herein. The installer of this equipment must ensure the antenna is located or oriented
such that it does not emit an RF field in excess guidelines as posted in the 47 CFR
Bulletin 65/47CFR ยง 1.1310 of the Federal Communications Commission, or the Council
of European Union as appropriate.
People should not be near the antenna when the radio link is operating as general
practice and maintain a safe distance as calculated below.
The following calculations are based off the Maximum Permissible Exposure
requirements as outlined by the FCC.
The MPED (Maximum Permissible Exposure Distance) is calculated based on the limits
for a General Population/Uncontrolled Exposure in the 300-1500 MHz frequency band
using the stated MPE power density limit of F/1500 mW/cm
2
for General Population
/Uncontrolled environment.