User's Manual
Xerox Nuvera™ 100/120/144 Digital Production System - Customer Expectations Document
- 35 - 
Basic Finishing Module (BFM) and BFM Plus
Dimensions  Basic Finishing Module (BFM) 
Width X Depth X Height  32.9” X 28” X 44.5” (835.7mm X 711.2mm X 1130.3mm) 
Weight   369 lbs. ( 167.4 kg) 
Clearance: Operator  Minimum 38” in front of module 
Clearance: Service  Minimum 30” from back wall 
Dimensions  Basic Finishing Module Plus (BFM Plus) 
Width X Depth X Height  48” X 28” X 44.5” (1220mm X 711.2mm X 1130.3mm) 
Weight   494 lbs. ( 167.4 kg) 
Clearance: Operator  Minimum 38” in front of module 
Clearance: Service  Minimum 30” from back wall 
BFM / BFM Plus 
Electrical & 
Environmental 
Minimum  Maximum 
Temperature Range 
50° F (10° C)  90° F (32.2° C) 
Humidity Range  15% RH  85% RH 
Altitude   0 ft  10,000 ft. (3048m) 
Power 
 200 - 240 VAC ± 10%, 50/ 60 Hz, 8Amps 
Media Latitude  BFM / BFM Plus 
Stock Weight Range 
Uncoated: 16lb. bond to 120lb. index (56 to 250 gsm) 
Coated: (90 to 250gsm) 
Stock Size Range  7” x 8” to 12” x 18.5” (178 x 203mm to 320mm x 470mm) – See table on following pages 
Top Tray Capacity  250 (20 lb. bond / 75 gsm) 
Main Stacker  3000 (20 lb. bond / 75 gsm) 
Stapler  One or two staples, up to 100 sheets (20 lb. bond / 75 gsm) 
System Compatibility
There are two models: the BFM has a top tray (also know as purge tray); the BFM Plus includes a bypass 
transport over the stacker 
Both the BFM and the BFM Plus may be installed to enable continuous running with unload-while-run. 
If one of these modules is the only installed finisher, it must be BFM (with the top tray). 
A single BFM Plus may be installed if connected to a downstream FTM to add supported inline DFA finishing 
BFM / BFM Plus Operation
Continuous operation with unload while run is fully supported with a BFM and
 BFM Plus installation. When a 
stacker is full or not ready (e.g. out of staples) the system can auto switch to another available stacker. 
Unloads can be configured to occur automatically at stacker limit, at job boundaries, at set or 
partition boundaries, or can be initiated manually via the Stacker Unload button or the GUI. A stacker's limit 
can be configured to any value between 200 and 3000 and each BFM stacker can be configured 
independently and differently. If desired, operators can also program jobs to specific stacker destinations.
Bypass via BFM Plus 
Bypass to a downstream finishing device is a capability of the BFM Plus 
BFM 
BFM Plus 










