Operating Instructions HOB Contents Installation, 2-5 GB English,1 Positioning Gas connection Data plate Burner and nozzle specifications Electrical connection,6 Description of the appliance, 7 Overall view Start-up and use, 8-9 Practical advice on using the burners Precautions and tips, 10 GF750TX GF761RFX General safety Disposal Recycling & Disposal Information Maintenance and care, 11 Switching the appliance off Cleaning the appliance Gas tap maintenance Troubleshooting, 12 Guarantee, 13 After Sal
Installation ! Before operating your new appliance please read this instruction booklet carefully. It contains important information for safe use, installation and care of the appliance. also be equipped with vents to allow gas to escape in the event of a leak. As a result LPG cylinders, whether partially or completely full, must not be installed or stored in rooms or storage areas that are below ground level (cellars, etc.).
There is an adjustable L-shaped pipe fitting on the appliance supply ramp and this is fitted with a seal in order to prevent leaks. The seal must always be replaced after rotating the pipe fitting (seal provided with appliance). The gas supply pipe fitting is a threaded 1/2 gas cylindrical male attachment.
GB Replacing the nozzles on separate “double flame “ burners: 1. remove the grids and slide the burners from their housings. The burner consists of 2 separate parts (see figure); 2. unscrew the burers with a 7 mm wrench spanner. The internal burner has a nozzle, the external burner has two (of the same size). Replace the nozzle with models suited to the new type of gas (see table 1). 3. replace all the components by repeating the steps in reverse order.
Burner and nozzle specifications GB Table 1 Liquid Gas Burner 100 Thermal power kW (p.c.s.*) Nozzle 1/100 ** Nomin. (mm) 189 186 2.60 110 (Y) 248 Thermal power kW (p.c.s.*) By-Pass 1/100 Nozzle 1/100 Ridot. Nomin. (mm) (mm) *** 0.70 2.60 39 80 Diameter Thermal (mm) power kW (p.c.s.* Reduced Fast (RR) Natural Gas Flow* g/h Flow* l/h Semi Fast (S) 75 0.40 1.90 28 70 138 136 1.90 106 181 Auxiliary (A) 55 0.40 1.00 28 50 73 71 1.
Electrical Connection GB Power supply voltage and frequency: 220-240V a.c. 50/60Hz. ! The supply cable must be positioned so that it never reaches at any point a temperature 50°C higher than the room temperature. The cable must be routed away from the rear vents. Should you require it, you may use a longer cable, however, you must ensure that the cable supplied with the appliance is replaced by one of the same specifications in accordance with current standards and legislation. rating of 45 amp.
Description of the appliance Overall view GB GAS BURNERS Support Grid for COOKWARE Control Knobs for GAS BURNERS SAFETY DEVICES * • GAS BURNERS differ in size and power. Use the diameter of the cookware to choose the most appropriate burner to cook with. • Control Knobs for GAS BURNERS adjust the power or the size of the flame. Ignition for GAS BURNERS * • GAS BURNER ignition* enables a specific burner to be lit automatically.
Start-up and use GB ! The position of the corresponding gas burner or electric hotplate* is shown on every knob. Gas burners Each burner can be adjusted to one of the following settings using the corresponding control knob: • Off Maximum Minimum To light one of the burners, hold a lit match or lighter near the burner and, at the same time, press down and turn the corresponding knob anti-clockwise to the maximum setting.
Practical Advice on Using the Half Fish-Kettle Burner * GB The two "Half Fish-Kettle" burners, are eliptic in form and can be turned up to 90°. This makes the cooktop more flexible in terms of how it can be used. To turn the two burners 90°, proceed as follows: • Make sure that the burners are cool; • Lift the burner completely out of its housing; • Replace it in its housing in the position desired; • Make sure that the burners are positioned correctly before use.
Precautions and tips GB ! This appliance has been designed and manufactured in compliance with international safety standards. The following warnings are provided for safety reasons and must be read carefully. General safety • This is a class 3 built-in appliance. • Gas appliances require regular air exchange to maintain efficient operation. When installing the hob, follow the instructions provided in the paragraph on “Positioning” the appliance.
Maintenance and care Switching the appliance off Gas tap maintenance Disconnect your appliance from the electricity supply before carrying out any work on it. Over time, the taps may become jammed or difficult to turn. If this happens, the tap must be replaced. Cleaning the appliance ! This procedure must be performed by a qualified technician authorised by the manufacturer.
Troubleshooting GB It may happen that the appliance does not function properly or at all. Before calling the service centre for assistance, check if anything can be done. First, check to see that there are no interruptions in the gas and electrical supplies, and, in particular, that the gas valves for the mains are open. Problem Possible causes/Solution The burner does not light or the flame is not even around the burner. • The gas holes on the burner are clogged.
Guarantee 12 months Parts and Labour Guarantee Your appliance has the benefit of our manufacturer’s guarantee, which covers the cost of breakdown repairs for twelve months from the date of purchase. This gives you the reassurance that if, within that time, your appliance is proven to be defective because of either workmanship or materials, we will, at our discretion, either repair or replace the appliance at no cost to you.
After Sales Service No one is better placed to care for your Hotpoint appliance during the course of its working life than us – the manufacturer. Essential Contact Information Hotpoint Service We are the largest service team in the country offering you access to 400 skilled telephone advisors and 1000 fully qualified engineers on call to ensure you receive fast, reliable, local service. UK: 08448 224 224 Republic of Ireland: 0818 313 413 www.hotpointservice.co.
Notes GB 15
Notes 06/2010 - 195084552.