Laser Printing System Message Guide

IFU (INTERPRESS FONT UTILITY) MESSAGES
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS MESSAGE GUIDE 5-17
IF2708 Syntax error: unexpected token x encountered
The character or symbol indicated in the message is incorrectly
included in the command line.
Action Reenter the command, omitting the incorrect character or symbol.
IF2709 Syntax error: literal exceeds x characters
The literal (an alphanumeric string not enclosed in single quotes)
exceeds the maximum number of allowable characters.
Action Reenter the command, using a literal with an allowable number of
characters.
IF2710 Syntax error: hex value is out of range
The command line contains a hexadecimal value that is not within the
allowable range.
Action Reenter the statement to include hex values that are within the
allowable range.
IF2711 Syntax error: invalid hex value
The command line contains an incorrect hexadecimal value.
Action Reenter the statement to include an acceptable hex value.
IF2712 Syntax error: unclosed string
A string (sequence of alphanumeric characters treated as a single
unit of data) must be enclosed in single quotes.
Action Reenter the command to include a string enclosed in single quotes.
IF2713 Syntax error: string exceeding x characters
The string exceeds the allowable numbers of characters.
Action Reenter the command to include a string with an allowable number
of characters.
IF2714 Syntax error: invalid character x has been encountered
The command line contains a character that is not allowed.
Action Reenter the command, using allowable characters.
IF2715 Syntax error: invalid command x has been encountered
The command requested is not allowed.
Action 1. Verify and reenter the command.
2. If the message reappears, contact your systems specialist or