OS Level 6: Job integrity
Identifies possible errors affecting output and what action(s), if any,
to take.
OS6000 Insufficient memory for ‘ACCTINFO’; Continue or Abort?
JSL specified the ‘ACCTINFO’ option of the RSTACK command.
There is not enough dynamic memory for it.
Action 1. Enter the CONTINUE command, or press the <CON> key to
print the job without delimiter sheets.
or
Enter the ABORT job command to cancel the job.
2. Recreate the job, reducing the number of features.
OS6005 Invalid Ethernet tape preamble format.
Information in the Ethernet tape header (preamble) is missing or
incorrectly formatted. Job will not print.
Action Recreate the job tape, ensuring that the data is formatted correctly.
(Refer to
Xerox LPS Tape Formats Manual.
)
OS6006 Invalid Ethernet print procedure message.
The Ethernet tape contains an incorrect sequence of bytes
describing procedures for printing. The job will not print.
Action Recreate the tape, ensuring that the print procedures information is
formatted correctly. (Refer to
Xerox LPS Tape Formats Manual
.)
OS6007 Ethernet tape job from this host type not supported.
The Ethernet tape contains information for which no PDL statement
exists and, therefore, cannot be incorporated into a JSL (e.g.,
packing information). The tape cannot be used.
Action None.
OS6008 Problem with Ethernet tape, checksum failed, check tape.
The Ethernet tape has apparent data loss. The job will not print.
Action Check the tape at the host to determine where the problem exists;
recreate the tape ensuring that data is complete. (Refer to
Xerox LPS
Tape Formats Manual.
)