PRINTER CONTROLLER MESSAGES
48-38 XEROX DOCUPRINT 4050/4090/4850/4890/92C NPS MESSAGES GUIDE
P013 GWR lost machine clock. There is a CDM or GWR board failure or a harness
problem between CDM and GWR.
No action required.
If the problem persists, notify your service representative.
P016 GWR failed memory/
communication test.
There is a GWR board failure.
No action required.
If the problem persists, notify your service representative.
P022 ADIO terminated
communication/other.
The ADIO board has terminated due to a communication
failure with the core board, or another ADIO problem
exists. Diagnostic LEDs on the ADIO distinguish the failure
type.
No action required.
If the problem persists, notify your service representative.
P027 GWR Core 8085 lost
communication with
8751.
Press the Continue button.
If the problem persists, notify your service representative.
P187 Polygon motor not up to
speed in 30 sec.
The polygon motor speed is not correct.
No action required.
If the problem persists, notify your service representative.
P189 EOS connector fault. The EOS cable assembly is not connected, or the 5V
power supply is missing on the EOS detector PWBA.
No action required.
If the problem persists, notify your service representative.
P190 SOS connector fault. The SOS cable assembly is not connected, or the 5V
power supply is missing on the SOS detector PWBA.
No action required.
If the problem persists, notify your service representative.
P192 ROS LV power supply out
of range.
30.5V is out of nominal range at the edge of the pixel clock
board.
No action required.
If the problem persists, notify your service representative.
P193 Power to pixel board out
of range.
One of three voltages, + 15V, -15V, or -5.2V, is out of
nominal range at the edge of the pixel clock.
No action required.
If the problem persists, notify your service representative.
P194 Input power to polygon
driver board out of range.
One of three voltages, +15V, -15V, or -5V, is out of
nominal range at the edge of the motor driver PWBA.
No action required. If the problem persists, notify your
service representative.