Operation Manual
Xerox DocuMate 4799
User’s Guide
187
Cleaning the ADF Rollers
1. Pull on the scanner cover release and lift the lid to open the scanner.
2. The following illustration shows where the rollers are located in the scanner.
Use a roller cleaning paper to clean all of the rollers indicated in the illustration.
Reset the Roller Count in the User Utility
After cleaning the scanner you need to reset the roller count in the User Utility.
1. Open the User Utility application.
Note: Be careful when cleaning the rollers. All of the rollers, except the free rollers, are designed to
rotate in one direction only. Do NOT force the roller to rotate in the opposite direction. Forcing the
roller to rotate will damage it, and cause the scanner to feed pages incorrectly.