2. Clean each corotron by slowly pulling out and pushing in the 
Cleaning Wand one time.
KEY POINT: To ensure proper cleaning of the pad, slowly pull out 
the wand until it reaches the end of the assembly
; it will stop 
when it reaches the end. Slowly push in the wand until it is fully 
seated against the corotron assembly.
CAUTION: To avoid damage to the corotron assembly, carefully 
and slowly
 pull out the Cleaning Wand. Once the wand reaches 
the end of the assembly, it stops. Do not continue to pull on the 
wand as this will remove the wand from the Corotron Assembly, 
thereby damaging the assembly. If this occurs, you must replace 
the entire Corotron Assembly.
Slowly pull out the wand,
then push it back in