User guide

DTP34 DENSITOMETER
7
Measurements
Measurement Notes and Tips
You should refer to the documentation for the software program that you are using with your instrument. All
applications that utilize this instrument must be running during measurements.
The strip must have at least a 1.2 (30.5mm) leader before the leading edge of the first step. Contact X-Rite
Applications Support if additional information is required. Inspect the strip for spots or defects on the steps.
Defects may cause inaccurate measurements.
If a strip does not have the necessary 1.2 (30.5mm) unprinted leader before the first patch or a reading would
cause one or more of the wheels to be off the sample, follow the steps listed below:
1. Obtain extra pieces of the sample stock.
2. Position the pieces so that all four wheels of the instrument ride along the same height stock when patches
are measured.
INCORRECT:
Wheels off the
edge of the paper
or insufficient
leader.
INCORRECT:
Wheels off the
edge of the paper.
SOLUTION: Place
extra stock here.
SOLUTION:
Place
extra stock here.