CALIBRATION
37
Calibrating with the DTP32 or DTP32 Series II
Using the DTP32 or DTP32 Series II densitometer, you can measure color patches generated
by the digital press and automatically download the measurements to the Fiery EXP8000/50.
NOTE: Before you use ColorWise Pro Tools to calibrate the Fiery EXP8000/50, set up and
calibrate the DTP32 or DTP32 Series II. For instructions, see the documentation that
accompanies the instrument.
TO CALIBRATE THE FIERY EXP8000/50 USING THE DTP32 OR DTP32 SERIES II
1 Start Calibrator.
For instructions, see page 33.
2 In the Select Measurement Method pane, choose X-Rite DTP32 or X-Rite DTP32 Series II.
3 In the Check Print Settings pane, choose a calibration set.
If more than one option appears, choose the appropriate calibration set for the type of media
and screen you use most often.
NOTE: For this calibration to take effect, the calibration set must be associated with one or
more output profiles. The default calibration set is already associated with the default output
profile. You do not need to make any new associations.
4 Click Print in the Generate Measurement Page pane.
The Print Options dialog box appears.
5 Choose the appropriate options and click Print.
Page Type: Choose 21 or 34 Sorted Patches.
Paper Size: Automatically set to LTR/A4 for 21 Sorted Patches. Choose 11x17/A3 or
12x18/SRA3 for 34 Sorted Patches.
Input Tray: Specify the paper source.
6 Retrieve the measurement page from the digital press.
7 Click Measure in the Get Measurements pane.
The Measurement Options dialog box displays the specified Page Type and
Paper Size options.