User's Manual

About PostScript Resolution (dpi)
PostScript Resolution (dpi): Choose either of the following options:
600x600x8
300x300x8
About Minimum Line Width
The Minimum Line Width option enables you to adjust the minimum line width within
a PDF job to control the thickness of the fine lines that they do not disappear during
printing.
Minimum Line Width: Use the Up and Down arrows to set the desired minimum line
width at both resolutions.
Note
The minimum value is 0 and the maximum value is 4.
About FreeFlow VI Project Container Filter (VPCF)
The VPC Filter reports error codes that are defined by the Global Fault Manager (GFM)
or the filter back to the GFM.
Select the check box if desired.
Managing Printer Queues
The Queue Manager provides flexibility: you can create a single queue through which
all jobs can be submitted, or you can create multiple queues each having its distinct
properties.
Note
When you enable the Override icon in Queue Manager for any queue property, that
selection applies to any jobs submitted to that queue and takes precedence over any
property selections that are made in the Job Manager or programmed into the job.
Only 250 queues can be created. However, you can also create up to 128 AppleTalk
connections. It is not recommended to use a large number of AppleTalk queues because
use of many queues degrades system performance. On systems with the AppleTalk
license disabled, 250 queues can be set up without performance degradation.
Note
AppleTalk support is discontinued with FreeFlow
®
Print Server 9.0 and higher.
4-37FreeFlow Print Server
Online Help
Queue Manager