User Manual
98 •Main Menu   XEROX WIDE FORMAT COPY SYSTEM 
IMAGE ENHANCEMENT
COLOR IQ: SRGB
IMAGE ENHANCEMENT
COLOR IQ:
 4DYNAMIC BACKGROUND REMOVAL
 SRGB
 NORMAL MODE:  BEST IQ
6.  Press the Next key to select the enhancement option you want: 
•  NONE: scanned color has no color correction applied. 
•  SRGB: scanned colors will be converted to the SRGB color 
space 
•  ADAPTIVE CONTRAST: scanned colors are first converted 
to the SRGB color space, then enhanced using an adaptive 
contrast algorithm. The adjustment changes the images 
white point, black point,  
NOTE: Further color halftone image enhancement can be achieved 
when printing by enabling the Error Diffusion Raster Halftone Method in 
the controller Web PMT. The setting is found on the Processing Defaults 
page. Select Error Diffusion from the Raster Halftone Method pull-down 
menu. 
7.  Press the Enter key the select the enhancement setting.  
8.  Press the Next key to select NORMAL MODE then press the 
Enter key to select Normal Mode. 
9.  Press the Previous of Next to scroll through the settings BEST 
IQ and FASTEST then press the Enter key to select the setting. 
BEST IQ is the default 
10. Press the Next key to select DYNAMIC BACKGROUND 
SUPPRESSION. Then press the Enter key to enable/disable 
DYNAMIC BACKGROUND REMOVAL. Disabling the DYNAMIC 
BACKGROUND REMOVAL enables the STATIC 
BACKGROUND REMOVAL. DYNAMIC BACKGROUND 
REMOVAL is the default and should be used for most document 
types 
11. Press the Enter key to confirm the selection. 
12. Press the Exit key to return to the CONFIGURATION menu. 
The TIMERS option of the CONFIGURATION menu allows you to set the 
values for the time-out functions. Pressing any key or scanning a 
document resets the timers. 
The timers are as follows: 
•  FEATURE - Controls how long the current feature parameters 
remain in effect after the last key press, scan completion, or 
insertion of a document into the Scanner. The FEATURE timer 
can be set between 0 and 99 minutes. The factory default is 5 
minutes. A value of 0 means that the feature will never time out. 
TIMERS 