Datasheet

XEROX
®
D110/ D125 COPIER-PRINTER CED
33
Environmental Factor
Recommended
Minimum
Maximum
Heat Emission / Output Standby:
1500 BTU/Hr
Approx.
50Hz - 7,516
BTU/Hr
60 Hz - 7,448
BTU/Hr
(Running)
Ventilation Requirements:
o Indoor air quality procedure-
An acceptable indoor environment contributes to productivity, comfort, and a sense of health and
well being. The minimum recommended exhaust rate for copy and printing rooms is 0.5 cfm/ft2
(cubic feet per minute per square foot of floor space). This must be replaced with an equal volume of
fresh, outside air or adequately filtered, recirculated air delivered with adequate mixing. For office
buildings, a minimum of 10% outside air is generally mixed with recirculated air. This is a method of
providing enough clean air to the space to be confident that emissions will be diluted to acceptable
levels.
*For greater detail regarding adequate venting for your Xerox equipment please refer to the
Customer Site Survey and the (IPD) Install Preparation Document or (IPG) for your appropriate
device.
NOTE 1: If above 90 Degrees F (32 Celsius), reduced relative humidity is required to
maintain the specific performance.
NOTE 2: For altitudes above 10,000 feet, equipment shutdown rates may increase.
22. Electrical Requirements
Please reference both the Customer Site Survey and the Installation Preparation Document.
The electrical outlet must be located within 6 feet (1828 mm) to the right of the right rear corner of the main
processor, or no more than 3 feet (914 mm) to the left of the left rear corner of the main processor (when facing
the machine). The outlet/circuit cannot be shared with any other devices or equipment.
Printer System (Western Hemisphere)
Main Processor
Optional
Controller
All Feeders and Finishers
(each require a separate electrical connection)
Nominal Voltage
208-240 VAC
(+6% to -10%)
100-240 VAC,
single phase (+6%
to -10%)
100-240 VAC, single phase (+6% to -
10%)
Amperage 13/15 3 13/15
Cycles 50/60 HZ 50/60 HZ 50/60 HZ