A-20 Appendix A
DocuTech 6155/6180 to FusionPunch II to
SBM2 –without CIM
Device Profile - Properties and Default Limits –
Timings Tab
(*) = For Each High Capacity Stacker on a DT6155 / 6180, Add 656ms To Sheet
and Set Jam Times.
(#) = For Each High Capacity Stacker Add 50ms To End of Set Offset.
Paper Sizes
Set Sizes
Non-Stream Feed /
Stream feed
8.5x11/8.5x14/A4
23 to 27 Sheet Set
Stream Feed
11x17/A3
1 to 27 Sheet Set
Non-Stream Feed /
Stream Feed
Time Between Sheets 120 120
Sheet Jam Time (*) 800 (*) 800 (*)
Set Compiler Processing
Time
600 150
Maximum Set
Processing Time
0 2400
Set Jam Time (*) 7168 (*) 7168 (*)
Time to Cycle Up 0 0
S0
Enabled Enabled
S1
Enabled Enabled
S2
Enabled Enabled
S3
Disabled Disabled
S4
Disabled Disabled
Delivery Signal Type Lead Edge Lead Edge
Delivery Start Adjust 0 0
Delivery End Adjust 50 50
End of Set Offset
(#) 20 20
Recovery Behavior SET SET
Finisher Capacity 7 7
Cycle Down Delay 0 0