Radiation Pattern
Operational and Environmental Specifications
Operational temperature
Cold
Dry heat (Long term, days/weeks/years)
Thermal shock
-40°F (-40°C)
+185°F (+85°C)
-40°F to 185°F (-40°C to +85°C); cycled
Application temperature
Cold
Dry heat (Short term, minutes/hours)
-40°F (-40°C)
+185°F (+85°C)
Humidity
Operational humidity
Storage humidity
5%-95% non-condensing
5%-95% non-condensing
Shock (drop) 3 ft (1 m) to concrete/granite up to 200 cycles
Vibration MIL-STD-810F
Compression strength 14.5 psi (100 kPa)
IP classification IP54
Product Dimensions and Weight
On-metal Off-metal
38 mm
13 mm
4.0 mm
Dimensions (mm) 38 x 13 x 4.0
tolerance +/- 0.35
Dimensions (in) 1.50 x 0.51 x 0.16
tolerance +/- 0.014
Weight 0.08 oz (2.3 g)
Order information
X0330-US011-M4 Data Trak II US
X0330-EU011-M4 Data Trak II EU