Operation Manual

17
EN
AGM
WITH COMPENSATION CHARGE
AGM, CALCIUM, SPIRAL
AGM, CALCIUM, SPIRAL
WITH COMPENSATION CHARGE
LiFe-PO4
The charger will leave the setup-mode if the button isn’t used for 10 seconds. In
this case the ‘ power’ LED will flash two times. The chosen setting will remain in
the memory of the charger and the setting LED lights when the charger is on.
Charger as power supply
The LBC 500XTR has a special setting for the use as a power supply. In this
case the charger will give one, constant voltage. The users can be connected to
the charger directly, so without intervention of a battery.
Put the charger in its set up mode, as described above. Push until all 4 setting
LED’s are out.
If the charger is in its power supply function, the three charge status LED’s are
used to indicate the height of the load. This way you know how much power the
charger supplies.
LED
Current
LED
Current
Green, flashes
0%
Yellow + red
61% - 80%
Green
1% - 20%
Red
81% - 100%
Green + yellow
21% - 40%
Red, flashes
> 100%
Yellow
41% - 60%
INSTALLATION
The atmosphere
The battery should be charged in an area with adequate ventilation because it
may emit explosive gases. Be sure that there is enough space around the
charger. This is important for the air circulation, for cooling of the charger and
release of gases emitted.
POWER SUPPLY
1 2 3 4
1 2 3 4
(flashing)
1 2 3 4
1 2 3 4
(flashing)
1 2 3 4