7000 User’s Guide Chapter 4
3. Select Beeper On to turn the beeper on or off. The beeper makes a sound to
indicate the results of operations such as Insertion Test error, ID unmatched,
programming successfully completed or failed.
NOTE: Not all programmers include a beeper.
4. Indicate the mode for verifying the data by selecting one of the Verify Mode
options. These options refer to the voltage of the pin VCC, which may vary
when the programmer verifies the data. The manufacturer provides the
MinVcc and MaxVcc values for verifying the data.
VCC(+/- 5%) or VCC(+/- 10%) is adopted for the verification. If VCC = 5.00V,
select one of the following options:
VCC = 5.00V and verify the data once
VCC = 4.75V and VCC = 5.25V, and verify the data twice (+/- 5%)
VCC=4.50V and VCC=5.50V, and verify the data twice (+/- 10%)
4.4.2 Buffer