User Manual
SUPERPRO
®
7000 User’s Guide Chapter 4
4.3.3.2 Fuse Buffer
When you select Edit from the Buffer menu with the appropriate file type, the
system opens the Fuse Buffer Edit window, illustrated below.
The data for editing is either 0 or 1. Refer to the data manual of the device and the
JEDEC to determine which of the following explanations for the data apply.
1 represents an intact fuse and 0 represents a blown fuse, or
1 represents a blown fuse and 0 represents an intact fuse
4.3.4 Device Configuration Word
Important: The device configuration word varies from device to device. Refer to the
device data manual for more information about the configuration words. Set the
configuration words according to the requirements of your target system. Otherwise,
you cannot use the device normally even if it is normal when preparing and
verifying the program.
32 of 51