User Manual

SUPERPRO
®
7000 User’s Guide Chapter 3
3.2.2 Load data into buffer
One can load data into the buffer by reading data either from a file or a master chip.
To read data from a file, select Load File from the File menu. The system
displays the Load File dialog box. To make sure the loaded data is correct one
can review the information in the Buffer window.
NOTE: Some Hex or S record files contain non‐zero file initial address. In this
case, enter the start address in the File Address box.
To read the data from a master chip, complete the following steps:
o Insert the master chip in the socket.
o Select Read on the Device Operation window in the main screen. The
data will be copied from the master chip to the buffer memory.
o To make sure the loaded data is correct one can review the
information in the Buffer window.
o If desired, you can save the data to a disk for later use.
NOTE: The read function is not available for some devices, including those
have been encrypted.
3.2.3 Set options
Click Operation Option from the Option menu to open the Operation Option
screen. Set each of the following options:
o Insertion Test indicates whether to check the pin contact.
o Device ID Check indicates whether to check the ID of the device.
o Beeper indicates whether the beeper alarms a sound when the
operation succeeds/fails.
o Auto Increment Function indicates an automatic increase in the label
number written to each chip.
17 of 51