0.5 1 2 3 6 10 20 30 60 120 180 300 600
1.75V A 8.0 7.2 6.5 5.3 5.2 3.6 1.8 1.4 0.74 0.44 0.34 0.22 0.12
25°C W 12.5 10.8 9.8 7.8 6.9 5.8 3.5 1.9 1.40 0.87 0.68 0.44 0.24
1.70V A 10.7 9.6 8.7 6.9 5.9 4.4 2.0 1.4 0.77 0.47 0.36 0.23 0.13
25°C W 17.2 14.7 13.3 10.8 8.9 6.4 3.9 2.4 1.50 0.91 0.72 0.45 0.25
1.60V A 13.9 12.2 10.8 8.5 7.0 5.1 2.2 1.5 0.83 0.48 0.37 0.24 0.13
25°C W 20.1 17.3 15.4 12.1 9.9 7.5 4.3 2.5 1.50 0.94 0.74 0.46 0.25
1.75V A 6.9 6.3 5.8 4.6 4.0 3.2 1.7 1.0 0.69 0.40 0.31 0.20 0.11
5°C W 11.0 9.9 9.2 7.3 6.5 5.5 3.1 1.8 1.21 0.74 0.58 0.39 0.21
1.70V A 9.6 8.8 7.9 6.3 5.3 4.0 1.8 1.2 0.73 0.42 0.33 0.21 0.12
5°C W 14.7 13.0 11.9 9.6 8.3 6.2 3.5 1.9 1.32 0.81 0.64 0.41 0.23
1.60V A 11.9 10.6 9.1 7.2 5.8 4.3 1.9 1.3 0.76 0.43 0.34 0.22 0.12
5°C W 18.4 16.1 14.3 11.6 9.7 6.4 3.9 2.1 1.43 0.83 0.65 0.42 0.23
FINAL VOLTAGE
TIME
Constant Current (Amp) and Constant Power (Watt/Cell) Discharge Table
Discharge Time (Minute)
to fi nal voltage / cell
Dimensions (mm)
+
-
52 1
58 1
T1
4.75
6.35
3.2
0
.8
44 1
97 1
Discharging Current & Discharge Duration Time
6.6
4.4
2.6
1.2
0.8
0.4
0.27
0.17
0.14
0.08
0.12
0.10
(h)
Discharge time
(min)
4
6
8
10
20
30
40
50
60
2
3
4
5
6
7
8
9
10
F
C
40 (104
)
25 ( 77
)
0 ( 32
)
0
F
C
F
C
Discharge Current (A)
Discharge Characteristics (25°C, 77°F)
h
min
3 5 12 24 35 60 2 3 5 10 200 1.5
3.6A 2.4A 1.2A
0.34A
0.22A
0.12A
0.065
A
Loading Voltage(V)
0.77A
13
12
11
10
10.5
9
9.6
8
Discharge Time
PHYSICAL SPECIFICATION
Nominal Voltage
Nominal Capacity (20HR)
12V
1.2AH
Dimension
Length
Width
Container Height
Total Height (with Terminal)
97 ± 1mm
44 ± 1mm
52 ± 1mm
58 ± 1mm
Weight Approx 0.60 kg
Standard Terminal T1(standard)
ELECTRICAL SPECIFICATION
Rated
Capacity
20 hour rate (mA)
10 hour rate (120mA)
5 hour rate (220mA)
1 hour rate (770mA)
15 minute rate (2.0 A)
1.3AH
1.2AH
1.1AH
0.77AH
0.50AH
Constant
Voltage
Charge
Cycle
Initial Charging Current
less than 0.36A. Voltage
14.4V~15.0V at 25°C (77°F)
Temp. Coeffi cient -30mV/°C
Capacity
affected by
Temperature
40°C (104°F)
25°C (77°F)
0°C (32°F)
103%
100%
86% Standby
No limit on Initial
Charging Current Voltage
13.5V~13.8V at 25°C (77°F)
Temp. Coeffi cient -20mV/°C
Internal
Resistance
Fully charged battery
(25°C, 77°F) 65mΩ
XCELL XP 1.2-12
12V 1.2 AH (20 HOUR)
BELTRONA GmbH & Co. KG
electronic components
Schmeienstraße 50
D-72510 Stetten a.k.M.
Telefon (0 75 73) 951 33 0
Telefon (0 75 73) 95 85 85
Telefax (0 75 73) 52 59
Telefax (0 75 73) 95 85 86
www.beltrona.de
info@beltrona.de
ISO9001
XP 1.2-12
VdS
G 114095