Datasheet

Document NO.: WI-FHF-CS-PMIIICSL-A Page 4of 9
MODEL: CS-PMIIICSL
REV: A/1
Notes():
1. Period of storage is counted from shipping date

2. Test Method and standard listed as below, environment temperature (1525), CC/CV
mode, 0.2C constant current charge to 4.2V, then constant voltage charge mode, cut off
current 0.01C0.2C constant current discharge, cut off voltage 3.0Vmore than 5 hours
discharging time.
(1525),CC/CV ,0.2C  4.2V,
, 0.01C 0.2C , 3.0V 5 
3.Test ()
3.1 Testing Environment:
3.1.1 Test time should be no more than one month after receive the battery
 1 .
3.1.2 Testing Environment():
Humidity(): 15--25
Relative Humidity(): 45%--85%
Atmospheric Pressure(): 76kPa--106kPa
3.2 Testing Instrument():
3.2.1 Voltage meter 0.5 grade or more regulated by IEC 51/IEC 485, more than 10K/V
internal resistance
 IEC 51/IEC 485  0.5 ,  10K/V
3.2.2 Current meter 0.5 grade or more regulated by IEC 51/IEC 485, include wire resistance
less than 0.01.
 IEC 51/IEC 485  0.5 ,  0.01.
3.2.3 Calipers Definition 0.02mm
  0.02mm
3.2.4 Internal Resistance Meter AC 1KHz 4 terminal measure setting.
  1KHz 4 .
3.2.5 Load Resistance Include external circuitry, allowed resistance figure error is ±5%.
 ,±5%.
3.2.6 Finished Battery Product Testing Machine
